GrowShop editorial guide
What are grow LEDs, PPFD, and DLI?
Watts describe electricity use, not the light a plant receives. Distribution, distance, photoperiod, and growing area must be considered together.
Core terms
| Term | What it describes | Sufficient on its own? |
|---|---|---|
| Watt | Fixture electricity use | No |
| PPFD | Photosynthetic photon density reaching a surface each second | Needs a map and test conditions |
| Photoperiod | Daily time the light is on | Assess with plant type and growth stage |
| DLI | Accumulated photosynthetic light over a day | Requires PPFD and duration |
When comparing products
One centre-point PPFD value does not describe distribution across the whole growing area.
- Is measurement height and coverage stated?
- Was the PPFD map made under comparable conditions?
- Are heat management and safety documents provided?
- Are hanging distance and photoperiod recommendations separated by plant type?
- Are warranty and driver details written down?
Distance and uniformity
Moving a fixture closer can increase intensity at some points while changing coverage and uniformity. Treat the manufacturer's distance guidance as a starting point and check plant response with an appropriate light measurement.
Calculate daily light from a constant PPFD
DLI (mol/m²/day) = PPFD (µmol/m²/s) × lighting hours × 0.0036. At a constant 300 µmol/m²/s for 16 hours, DLI is 17.28 mol/m²/day. This is an arithmetic example, not a crop target. A single sunlight reading cannot represent a whole day; varying light must be integrated over time.
References: Apogee Instruments
Compare lighting on the same basis
- Use the same mounting height and growing area when comparing PPFD maps.
- Check edge readings as well as the centre; a single peak value does not describe uniformity.
- Ask for the measured power draw, test conditions and manufacturer warranty.
- Separate a calculated light total from evidence that a particular crop needs it.
References: University of Minnesota Extension
DLI calculator
For constant artificial light. Enter the PPFD at canopy level and daily lighting hours.
Formula: PPFD × hours × 0.0036. This estimates light exposure, not a crop recommendation. For changing sunlight, use measurements integrated over time.